X-Git-Url: https://zdv2.bktei.com/gitweb/EVA-2020-02-2.git/blobdiff_plain/e5c4d98c8afe7b3fda44fd8c9951a454a53112bf..bca04496c248701cca287451021eed9f3c7389ed:/examples/all-in-one.py diff --git a/examples/all-in-one.py b/examples/all-in-one.py index 8e82b6b..87acc6f 100755 --- a/examples/all-in-one.py +++ b/examples/all-in-one.py @@ -5,17 +5,28 @@ import colorsys import os import sys import ST7735 -import ltr559 +try: + # Transitional fix for breaking change in LTR559 + from ltr559 import LTR559 + ltr559 = LTR559() +except ImportError: + import ltr559 from bme280 import BME280 -from pms5003 import PMS5003 +from pms5003 import PMS5003, ReadTimeoutError as pmsReadTimeoutError from enviroplus import gas from subprocess import PIPE, Popen from PIL import Image from PIL import ImageDraw from PIL import ImageFont +import logging + +logging.basicConfig( + format='%(asctime)s.%(msecs)03d %(levelname)-8s %(message)s', + level=logging.INFO, + datefmt='%Y-%m-%d %H:%M:%S') -print("""all-in-one.py - Displays readings from all of Enviro plus' sensors +logging.info("""all-in-one.py - Displays readings from all of Enviro plus' sensors Press Ctrl+C to exit! @@ -64,7 +75,7 @@ def display_text(variable, data, unit): - min(values[variable]) + 1) for v in values[variable]] # Format the variable name and value message = "{}: {:.1f} {}".format(variable[:4], data, unit) - print(message) + logging.info(message) draw.rectangle((0, 0, WIDTH, HEIGHT), (255, 255, 255)) for i in range(len(colours)): # Convert the values to colours from red to blue @@ -86,7 +97,6 @@ def display_text(variable, data, unit): def get_cpu_temperature(): process = Popen(['vcgencmd', 'measure_temp'], stdout=PIPE, universal_newlines=True) output, _error = process.communicate() - output = output.decode() return float(output[output.index('=') + 1:output.rindex("'")]) @@ -94,10 +104,10 @@ def get_cpu_temperature(): # temperature down, and increase to adjust up factor = 0.8 -cpu_temps = [0] * 5 +cpu_temps = [get_cpu_temperature()] * 5 delay = 0.5 # Debounce the proximity tap -mode = 0 # The starting mode +mode = 0 # The starting mode last_page = 0 light = 1 @@ -131,7 +141,7 @@ try: # One mode for each variable if mode == 0: - variable = "temperature" + # variable = "temperature" unit = "C" cpu_temp = get_cpu_temperature() # Smooth out with some averaging to decrease jitter @@ -139,70 +149,82 @@ try: avg_cpu_temp = sum(cpu_temps) / float(len(cpu_temps)) raw_temp = bme280.get_temperature() data = raw_temp - ((avg_cpu_temp - raw_temp) / factor) - display_text(variable, data, unit) + display_text(variables[mode], data, unit) if mode == 1: - variable = "pressure" + # variable = "pressure" unit = "hPa" data = bme280.get_pressure() - display_text(variable, data, unit) + display_text(variables[mode], data, unit) if mode == 2: - variable = "humidity" + # variable = "humidity" unit = "%" data = bme280.get_humidity() - display_text(variable, data, unit) + display_text(variables[mode], data, unit) if mode == 3: - variable = "light" + # variable = "light" unit = "Lux" if proximity < 10: data = ltr559.get_lux() else: data = 1 - display_text(variable, data, unit) + display_text(variables[mode], data, unit) if mode == 4: - variable = "oxidised" + # variable = "oxidised" unit = "kO" data = gas.read_all() data = data.oxidising / 1000 - display_text(variable, data, unit) + display_text(variables[mode], data, unit) if mode == 5: - variable = "reduced" + # variable = "reduced" unit = "kO" data = gas.read_all() data = data.reducing / 1000 - display_text(variable, data, unit) + display_text(variables[mode], data, unit) if mode == 6: - variable = "nh3" + # variable = "nh3" unit = "kO" data = gas.read_all() data = data.nh3 / 1000 - display_text(variable, data, unit) + display_text(variables[mode], data, unit) if mode == 7: - variable = "pm1" + # variable = "pm1" unit = "ug/m3" - data = pms5003.read() - data = data.pm_ug_per_m3(1.0) - display_text(variable, data, unit) + try: + data = pms5003.read() + except pmsReadTimeoutError: + logging.warn("Failed to read PMS5003") + else: + data = data.pm_ug_per_m3(1.0) + display_text(variables[mode], data, unit) if mode == 8: - variable = "pm25" + # variable = "pm25" unit = "ug/m3" - data = pms5003.read() - data = data.pm_ug_per_m3(2.5) - display_text(variable, data, unit) + try: + data = pms5003.read() + except pmsReadTimeoutError: + logging.warn("Failed to read PMS5003") + else: + data = data.pm_ug_per_m3(2.5) + display_text(variables[mode], data, unit) if mode == 9: - variable = "pm10" + # variable = "pm10" unit = "ug/m3" - data = pms5003.read() - data = data.pm_ug_per_m3(10) - display_text(variable, data, unit) + try: + data = pms5003.read() + except pmsReadTimeoutError: + logging.warn("Failed to read PMS5003") + else: + data = data.pm_ug_per_m3(10) + display_text(variables[mode], data, unit) # Exit cleanly except KeyboardInterrupt: