Prep for v0.0.2
[EVA-2020-02-2.git] / examples / all-in-one.py
index 87840901fd5efd3610d2aecbb943ed6c27432d41..c0423e6d6a54f3cfaf6dcbf880edc03eda0f72d1 100755 (executable)
@@ -1,19 +1,25 @@
-#!/usr/bin/env python
+#!/usr/bin/env python3
 
 import time
 import colorsys
 import os
 import sys
 import ST7735
-import ltr559
+try:
+    # Transitional fix for breaking change in LTR559
+    from ltr559 import LTR559
+    ltr559 = LTR559()
+except ImportError:
+    import ltr559
 
 from bme280 import BME280
-from pms5003 import PMS5003
+from pms5003 import PMS5003, ReadTimeoutError as pmsReadTimeoutError
 from enviroplus import gas
 from subprocess import PIPE, Popen
 from PIL import Image
 from PIL import ImageDraw
 from PIL import ImageFont
+from fonts.ttf import RobotoMedium as UserFont
 import logging
 
 logging.basicConfig(
@@ -52,8 +58,8 @@ HEIGHT = st7735.height
 # Set up canvas and font
 img = Image.new('RGB', (WIDTH, HEIGHT), color=(0, 0, 0))
 draw = ImageDraw.Draw(img)
-path = os.path.dirname(os.path.realpath(__file__))
-font = ImageFont.truetype(path + "/fonts/Asap/Asap-Bold.ttf", 20)
+font_size = 20
+font = ImageFont.truetype(UserFont, font_size)
 
 message = ""
 
@@ -97,12 +103,12 @@ def get_cpu_temperature():
 
 # Tuning factor for compensation. Decrease this number to adjust the
 # temperature down, and increase to adjust up
-factor = 0.8
+factor = 2.25
 
 cpu_temps = [get_cpu_temperature()] * 5
 
 delay = 0.5  # Debounce the proximity tap
-mode = 0  # The starting mode
+mode = 0     # The starting mode
 last_page = 0
 light = 1
 
@@ -193,25 +199,33 @@ try:
             unit = "ug/m3"
             try:
                 data = pms5003.read()
-            except pms5003.ReadTimeoutError:
-                pass
+            except pmsReadTimeoutError:
+                logging.warn("Failed to read PMS5003")
             else:
-                data = data.pm_ug_per_m3(1.0)
+                data = float(data.pm_ug_per_m3(1.0))
                 display_text(variables[mode], data, unit)
 
         if mode == 8:
             # variable = "pm25"
             unit = "ug/m3"
-            data = pms5003.read()
-            data = data.pm_ug_per_m3(2.5)
-            display_text(variables[mode], data, unit)
+            try:
+                data = pms5003.read()
+            except pmsReadTimeoutError:
+                logging.warn("Failed to read PMS5003")
+            else:
+                data = float(data.pm_ug_per_m3(2.5))
+                display_text(variables[mode], data, unit)
 
         if mode == 9:
             # variable = "pm10"
             unit = "ug/m3"
-            data = pms5003.read()
-            data = data.pm_ug_per_m3(10)
-            display_text(variables[mode], data, unit)
+            try:
+                data = pms5003.read()
+            except pmsReadTimeoutError:
+                logging.warn("Failed to read PMS5003")
+            else:
+                data = float(data.pm_ug_per_m3(10))
+                display_text(variables[mode], data, unit)
 
 # Exit cleanly
 except KeyboardInterrupt: